Page 9 - April-Month
P. 9

TECHNICAL PAPER



             chloride and carbonated exposure, organic inhibitor   7.
             reduces the corrosion rate, while inorganic inhibitor fails to
             do so.                                             The authors gratefully acknowledge the financial support
                                                                provided by the Atomic Energy Regulatory Board under
         3.   Chloride and carbonation profile suggest that, AB acts as   Committee for Safety Research Programmes (Sanction No.
             a pore blocker whereas TEP fails to resist the movement of   AERB/CSRP/73/02/19). The authors also acknowledge Dr.
             aggressive ions which leading to corrosion of embedded   Vijay Luxami (Associate professor, School of Chemistry and
             steel rebar.
                                                                Biochemistry, TIET) for providing the helpful suggestion for this
                                                                research.
         6.  FUTURE SCOPE
         The ability of an RC structure to withstand aggressive   REFERENCES
         environmental actions, while at same time able to maintain   [1]   Tumidajski, P. J., & Chan, G. W. (1996). “Effect of sulfate
         its performance well above a minimum acceptable level is   and carbon dioxide on chloride diffusivity”, Cement and
         defined as ‘durability’. Effective service life of an RC structure is   Concrete Research, Vol. 26, No. 4, pp. 551-556.
         defined as the time period for which the structure, or a structural   [2]   Lee, M. K., Jung, S. H., & Oh, B. H. (2014). “Effects of
         element, can be used for its indented purpose without the need   carbonation on chloride penetration in concrete”.
         for maintenance. Deterioration of concrete structures concludes   ACI Materials Journal, V. 110, No. 5, pp. 559-566.
         that 50% of all cases of deterioration considered were caused   [3]   Ye, H., Jin, X., Fu, C., Jin, N., Xu, Y., & Huang, T. (2016).
         by corrosion of reinforcement, from chloride penetration or   “Chloride penetration in concrete exposed to cyclic drying-
         carbonation  , emphasis should be paid on utilizing service-life   wetting and carbonation”. Construction and Building
                   [40]
         estimation tools (SLT) on such types of deterioration processes   Materials, Vol. 112, pp. 457-463.
         as they can be vital aids. After all, the prospect that a structure   [4]   Al-Otaibi, M. S., Al-Mayouf, A. M., Khan, M., Mousa, A. A.,
         is durable can only be accessed through tools simulating the   Al-Mazroa, S. A., &Alkhathlan, H. Z. (2014). “Corrosion
         deterioration processes to which the structure is likely to be   inhibitory action of some plant extracts on the corrosion
         subjected.                                                 of mild steel in acidic media”. Arabian Journal of
                                                                    Chemistry, Vol. 7, No. 3, pp. 340-346.
         Service Life Modelling (SLM) is intended to allow quantification
         of the design service life of structures, for purposes of economic   [5]   Obot, I. B., Obi-Egbedi, N. O., &Umoren, S. A. (2009).
         optimisation, operational efficiency, and sustained structural   Antifungal drugs as corrosion inhibitors for aluminium in 0.1
         and aesthetic performance. One of the principal challenges in   M HCl. Corrosion Science, Vol. 51, No. 8, pp. 1868-1875.
         developing a mathematical model for service life prediction is   [6]   Królikowski, A., &Kuziak, J. (2011). “Impedance study on
         that many parameters, including material characteristics, climatic   calcium nitrite as a penetrating corrosion inhibitor for steel in
         environment, and construction method, will all affect service life.   concrete”. Electrochimicaacta, Vol. 56, No. 23, pp. 7845-7853.
         The service life of a reinforced concrete structure can be divided   [7]   Popov, B. N. (2015). “Corrosion engineering: principles and
         into two stages, the initiation period and the propagation   solved problems”. Elsevier.
         period.  In service life estimation, it is common to conservatively   [8]   Raja, P. B., Ismail, M., Ghoreishiamiri, S., Mirza, J., Ismail,
         assume the service life end when corrosion initiates.      M. C., Kakooei, S., & Rahim, A. A. (2016). “Reviews on
                                                                    corrosion inhibitors: a short view”. Chemical Engineering
         So far, various models have been proposed, such as empirical   Communications, Vol. 203, No. 9, pp. 1145-1156.
         models, statistical models, numerical models and simulation
         models. Most models cover either service life prediction of   [9]   Ormellese, M., Lazzari, L., Goidanich, S., Fumagalli, G.,
         structure subjected to chloride induced corrosion  [41-45]  or   & Brenna, A. (2009). “A study of organic substances
         carbonation induced corrosion  [46-47] . But these models cannot   as inhibitors for chloride-induced corrosion in
                                                                    concrete”. Corrosion Science, Vol. 51, No. 12, pp. 2959-2968.
         be valid for combined (chloride and carbonation ingress)
         environment due to various uncertainty in data.        [10]  Malik, A. U., Andijani, I., Al-Moaili, F., &Ozair, G. (2004).
                                                                    “Studies on the performance of migratory corrosion
         The above study concludes that organic inhibitors able     inhibitors in protection of rebar concrete in Gulf seawater
         to restrict the chloride and carbon-dioxide penetration in   environment”. Cement and concrete composites, Vol. 26,
         combined environmental exposure. This can be related with the   No. 3, pp. 235-242.
         increase in corrosion initiation period and increment in service   [11]  Fedrizzi, L., Azzolini, F., &Bonora, P. L. (2005). “The use of
         life of reinforced structure subjected to real environmental   migrating corrosion inhibitors to repair motorways’ concrete
         exposure of RC structure. In order to contribute with the service   structures contaminated by chlorides”. Cement and
         life prediction of the structures when inserted in combined saline   Concrete Research, Vol. 35, No. 3, pp. 551-561.
         and CO 2  environments with admixed inhibitor, a mathematical   [12]  Jamil, H. E., Shriri, A., Boulif, R., Bastos, C., Montemor, M.
         model need to be developed.                                F., & Ferreira, M. G. S. (2004). “Electrochemical behaviour of


                                                                             THE INDIAN CONCRETE JOURNAL | APRIL 2021  35
   4   5   6   7   8   9   10   11   12